​Standard debugging of electronic crane scale

Keyword:electronic crane scale   Time:2019-11-13 9:34:52

Standard debugging of electronic crane scale
 The standard debugging of the electronic crane scale directly affects the weighing accuracy and use quality of the electronic crane scale. The careful and standard operation of the debugging workers is very important, which requires our technical workers to work conscientiously, responsibly and meticulously. At the same time, users understand the electronic crane scale debugging can help you better understand their own products and help select the electronic crane scale products. What are the common methods in the commissioning of electronic crane scale?
 Common methods for commissioning and testing of electronic crane scales:
 (1)  load and record the indication value (test and record the integral error) in each load-bearing area along the longitudinal direction of the electronic crane scale. Compare all values and look for values near the middle as the canonical values. Move the load to another area and adjust the difference between the indicated value and the normal value. If it is lower than the standard value, the corresponding difference will be adjusted to a higher value, and if it is higher than the standard value, the corresponding difference will be adjusted to a lower value.
 Note: after adjustment, its zero point will usually be changed, so will the indicated value of a certain point. It will be adjusted under the indicated value of  existing load, and the adjusted fluctuation will be the difference between the indicated value before normalization and the specified value.
 (2)  remove the load, clear zero, basically satisfied with the requirements of the procedure. However, if there is any error, repeat the above operation with the error point (2).
 (3)  first ensure that the electronic crane scale device is correct, according to the order after the partial load test, select a potentiometer to be adjusted. When adjusting the potentiometer, pay attention to the investigation of the potentiometer to adjust the number of turns, direction and indicated value change, can be a pre-adjustment. That is, each error point is approximated to the target value. For example, when the potentiometer turns clockwise once, the indicator jumps up by one degree. The potentiometer against the target value can be adjusted to the desired position.
 The last thing I want to say is that the standard debugging of the electronic crane scale directly affects the weighing accuracy and use quality of the electronic crane scale. The careful and standard operation of the debugging workers is very important, which requires our technical workers to work seriously, responsibly and meticulously. At the same time, users understand the electronic crane scale debugging can help you better understand their own products and help select the electronic crane scale products.
 Above is the electronic crane scale standard debugging, electronic crane scale not  only has a very high work efficiency, the effect is very good, and the field of application is very wide.
 Safety measures before hoisting operation of electronic crane scale
 Before the hoisting operation, the hoisting operation plan should be prepared first so that the whole hoisting operation can be reasonably planned and guided. Secondly, the relevant staff should carefully check the equipment before lifting, to ensure that the equipment is in good condition, and at the same time, the actual implementation of safety measures should be verified, so as to facilitate safe construction; Carry out a comprehensive inspection of the warning signs, signs, warning areas and other relevant safety warning facilities within the lifting area, and require the construction personnel entering the lifting area to wear good appliances to ensure their personal safety.